Analog refractometer Urea/EG/PG/CW/BF ORA4UB - KERN
-
Suitable for the automotive and chemical industries
-
Intuitive adjustment
-
Low tolerance measurement
Analog Urea/EG/PG/CW/BF Refractometer - ORA 4UB KERN
The KERN ORA 4UB refractometer allows for the measurement and determination of AdBlue, ethylene and propylene glycol concentrations, battery fluid, urea, as well as the freezing point of wetting water.
The models in the KERN ORA-B series are universal manual and analog refractometers that require no maintenance. Their design has been specifically created to make them robust, practical, and durable tools. You can easily avoid human errors with a multiple choice graduation scale.
Due to their design, these scales are calculated and controlled with great precision, easily distinguishable by fine lines. Additionally, the optical system and prism cover allow for low-tolerance measurements. Each eyepiece has an intuitive and smooth adjustment for different visions.
This refractometer is particularly suitable for the automotive and chemical industries, forestry, and geothermal applications.
Additional Information:
This reference includes:
- A storage case
- Calibration solution
- A pipette
- A screwdriver
- A cleaning cloth
If you want to learn more about the possibilities offered by this product and to determine the accessories that best suit your needs, feel free to consult the downloadable documentation available in the Documentation tab. Accessories are also available in the Related Products and Resources tab.
If you cannot find the product or accessory you are looking for, or if you need advice on configuring the ideal device, do not hesitate to contact us.
Écran | Non |
Compensation et correction automatique | Non |
Nombre d'échelles | 5 |
Gamme de mesure | -50 à 0 °C EG et PG / -40 à 0 °C CW / 1,10 - 1,40 kg/l BF / 30 à 35 % Urée |
Type | Manuelle |
Échelle | Éthylène Glycol, Liquide de piles (BF), Propylène Glycol, Urea |
Caractéristiques techniques
Measurement temperature without ATC (Temperature Compensation): 20°C
Box dimensions LxWxH: 205x75x55 mm
Approximate length: 130 to 200 mm
Net weight approximately: 135 to 600 g
Graduation: Ethylene glycol (G11/12)
Measurement range: -50 to 0°C
Division: 1°C
Graduation: Propylene glycol (G13)
Measurement range: -50 to 0°C
Division: 1°C
Graduation: Urea and freezing point of wet point (CW)
Measurement range: -40 to 0°C
Division: 5°C
Graduation: Battery liquid (BF)
Measurement range: 1.10 - 1.40 kg/l
Division: 0.01 kg/l
Graduation: Urea
Measurement range: 30 to 35%
Division: 0.2%
|