Température : ambiante +10 °C +80 °C
Stabilité : ±0,2 °C
Homogénéisation : 0,3 °C à 37°C
Type d'affichage : Digital
Natural convection incubator IN30 - MEMMERT
SKU | Capacité | Price | Available | Amount Basket | ||
---|---|---|---|---|---|---|
707481 | 108 L |
€2,307.90
€2,769.48
|
On order |
|
||
707482 | 161 L |
€3,073.35
€3,688.02
|
On order |
|
||
707483 | 256 L |
€4,060.35
€4,872.42
|
On order |
|
||
707478 | 32 L |
€1,339.79
€1,607.75
|
On order |
|
||
707484 | 459 L |
€5,407.50
€6,489.00
|
On order |
|
||
707479 | 53 L |
€1,652.71
€1,983.25
|
On order |
|
||
707480 | 74 L |
€1,958.24
€2,349.89
|
On order |
|
||
707485 | 749 L |
€7,175.71
€8,610.85
|
On order |
|
Bacteriological incubators MEMMERT
Color display of temperature, time, fan speed, and air flap opening. SetpointWAIT function (start of countdown time when setpoint is reached). TB safety thermostat.
Intuitive 'Touch, turn and go' control. Door can be opened with elbow or foot.
Equipment of the SingleDISPLAY model
Temperature
Temperature up to 80°C
Temperature range: +5° for IN versions up to 80°C, stability
Range of useful temperatures: At least 10° above ambient temperature up to 80.
Display resolution of setpoint temperature and actual temperature values: 0.1 °C
Temperature: 2 Pt100 DIN A class thermosensors in 4-wire technology with mutual monitoring and maintenance of operation at exactly the same temperature.
Regulation technique
ControlCOCKPIT: SingleDISPLAY. Adaptive multifunctional microprocessor PID digital regulator with 2 high-resolution TFT color screens.
Language configuration: German, English, French, Spanish, Polish, Czech, Hungarian.
Clock: Digital timer with programmable stop time and duration setting from 1 minute to 99 days.
HeatBALANCE function: Adaptation of thermal power distribution between upper and lower heating elements in a range of -50% to +50%.
SetpointWAIT function: Start of the process only when the setpoint temperature is reached.
Calibration: Three selectable temperature values.
Adjustable parameters: Temperature (Celsius or Fahrenheit), air circulation motor speed, air flap position, program durations, time zones, daylight saving time/winter time.
Sterilization: Fixed sterilization program (4 h/160 °C) for sterilization of the internal chamber but not the loading element.
Aeration
Air turbine: Electronic adjustment in increments of 10%, silent, segment-specific.
Fresh air supply: Electronic adjustment in increments of 10%, segment-specific.
Air outlet: Connection for air outlet with flap, electronic adjustment.
Ambient temperature: +5 ºC to +40 ºC
Humidity h.r.: max. 80%, non-condensing.
Communication
Status recording: Program cycle recording in case of power failure
Programming: Programming, management, and downloading of programs from an Ethernet interface or USB port using AtmoCONTROL software.
Safety
Thermal safety device: Mechanical TB temperature limiter of protection class 1 (DIN 12880) for heating cut-off at about 20 °C above the maximum device temperature.
Thermal safety device: Selectable thermostat (protection class 3.1) or temperature limiter (protection class 2) on the screen.
AutoSAFETY: Integrated additional thermal safety device with alarm for automatic setpoint monitoring, which automatically monitors the setpoint value within a freely defined range, alarm in case of exceeding upper/lower threshold, heating cut-off in case of overheating.
Self-diagnostic system: For anomaly detection
Alarm: Visual and audible
Basic equipment
Shelves: 2 stainless steel grid(s), electropolished for capacities greater than or equal to 75L
Standard content: Factory calibration certificate at +37 °C included
Door: Inner glass doors
.
Alimentation | 220 V |
Plage de régulation de la température | Ambient temperature +5 to 80 °C |
Stabilité | ±0,3 °C |
Type d'affichage | Couleur |
Caractéristiques techniques
|