CO2 Incubator ICO150 - MEMMERT

Sku: 708277
Memmert
The strong points
  • Easy to clean

  • Sterilization program: 60 minutes at 180°C

  • Temperature data recording

€8,139.60 €9,767.52
- +
On order

The only difference between the ICO model and ICOmed is the CE medical certification for use in medical diagnostics. Standard Component Control CO2 Control: Electronic and digital regulation of CO2, in double-beam NDIR procedure, self-diagnosis and audible anomaly message, barometric compensation of air pressure CO2 Display Range: 0 to 20% CO2 Setting Accuracy: 0.1% CO2 Accuracy Deviation: +/- 0.2% O2 Display Precision: 0.1% Humidity Hygrometric regulation (standard): Humidity limitation by Peltier element; ensures humidity limitation of the inner chamber at 93% rh +/- 2.5% with water-filled tray introduced into the inner chamber. Humidity Display Accuracy: 0.5% rh Temperature Usable temperature range: 5°C above ambient temperature to +50°C Incorporated sterilization program: 60 minutes at 180°C (probes can remain in place) Displayable temperature range: +18 to +50°C Display resolution for setpoint and actual temperature values: 0.1°C Temperature: 2 Pt100 DIN A class four-wire thermosensors with mutual monitoring and maintenance of operation at exactly the same temperature Regulation Technique ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID microprocessor controller with 2 high-resolution TFT color screens Language Configuration: German, English, French, Spanish, Polish, Czech, Hungarian SetpointWAIT Function: Process starts only when set temperature is reached Adjustable parameters: temperature (Celsius or Fahrenheit), fan speed, CO2, program duration, time zones, daylight saving time Communication Interface: Ethernet LAN, USB State recording: Program cycle recording in case of power failure Programming: Programming, management, and program download from an Ethernet interface or USB port using AtmoCONTROL software Safety AutoSAFETY: Integrated additional thermal safety device with alarm for automatic monitoring of setpoint, which automatically monitors the set value within a freely defined range, alarms in case of exceeding upper/lower threshold, heating function cut-off in case of overheating or cooling function cut-off in case of undercooling Automatic diagnostic system: For anomaly detection in temperature and CO2 control, as well as for hygrometric threshold regulation Alarm: Visual and audible Heating Concept Full Heating: Multifunctional full-surface heating system with additional heating of the door and rear wall to prevent condensation formation Warranty: 3 years

Alimentation 220 V / 50 Hz
Nombre max de clayettes 10
Nombre de clayettes livrées 2
Dimensions intérieures (L x H x P) 560 x 700 x 400 mm
Dimensions extérieures (L x H x P) 19 x 1070 x 591 mm
Plage de régulation de la température Ambient temperature +5 to 50 °C
Capacité 156 L
Type de portes Portes doubles
Puissance 2000 W
Masse 90 kg
Stabilité ± 0,1 °C
Type d'affichage Ecran numérique
Caractéristiques techniques
Double Pt100 probe Homogeneity at 37°C +/-0.3
CO2 display accuracy 0.1%
Power supply 230V