Natural convection incubator IN30+ - MEMMERT

Sku: Pr_243508
Memmert
The strong points
  • From 32 to 749 L

  • AtmoCONTROL Software

  • Thermal safety

From €2,235.45 €2,682.54 €0.00 eco-part
Configuration

Model
SKU Capacité Price Available Amount Basket
707489 108 L
€3,195.15 €3,834.18
On order
+
707490 161 L
€3,984.74 €4,781.69
On order
+
707491 256 L
€4,854.15 €5,824.98
On order
+
707486 32 L
€2,235.45 €2,682.54
On order
+
707492 459 L
€6,310.50 €7,572.60
On order
+
707487 53 L
€2,521.05 €3,025.26
On order
+
707488 74 L
€2,845.50 €3,414.60
On order
+
707493 749 L
€8,119.65 €9,743.58
On order
+

Bacteriological incubators MEMMERT

Color display of temperature, time, fan speed, and air flap opening. SetpointWAIT function (start of countdown when setpoint is reached). TB safety thermostat.
Intuitive 'Touch, turn and go' control. Door can be opened with elbow or foot.

TwinDISPLAY model equipment

Temperature

Temperature up to 80°C
Temperature range: +5° for IN versions up to 80°C, stability +/- 0.3° at 37°C, homogeneity +/- 0.6°C at 37°C.
Useful temperature range: At least 10° above ambient temperature up to 80.

Display resolution of setpoint and actual temperature values: 0.1 °C
Temperature: 2 Pt100 DIN A class thermosensors in 4-wire technology with mutual monitoring and maintenance of operation at exactly the same temperature.

Regulation technique

ControlCOCKPIT: TwinDISPLAY. Adaptive multifunction digital PID microprocessor controller with 2 high-resolution color TFT screens.

Language configuration: German, English, French, Spanish, Polish, Czech, Hungarian.
Clock: Digital timer with programmed stop time and duration setting from 1 minute to 99 days.
HeatBALANCE function: Adaptation of thermal power distribution between upper and lower heating elements in a range of -50% to +50%.
SetpointWAIT function: Start of the process only when the setpoint temperature is reached.
Calibration: Three selectable temperature values.

Adjustable parameters: Temperature (Celsius or Fahrenheit), air circulation motor speed, air flap position, program duration, time zones, daylight saving time/winter time.
Sterilization: Fixed sterilization program (4 h/160 °C) for sterilizing the internal chamber but not the load.

Aeration

Air turbine: Electronic adjustment in 10% increments, quiet, segment-specific.
Fresh air supply: Electronic adjustment in 10% increments, segment-specific.
Air outlet: Connection for air outlet with flap, electronic adjustment.

Ambient temperature: +5 ºC to +40 ºC
Humidity h.r.: max. 80%, non-condensing

Communication

State recording: Program cycle recording in case of power failure
Programming: Programming, management, and program download from an Ethernet interface or USB port using AtmoCONTROL software.

Safety

Thermal safety device: Mechanical TB temperature limiter of protection class 1 (DIN 12880) for heating cut-off at about 20 °C above the maximum device temperature.
Thermal safety device: Thermostat (protection class 3.1) or temperature limiter (protection class 2) selectable on the screen.

AutoSAFETY: Integrated additional thermal safety device with alarm for automatic monitoring of the setpoint, which automatically monitors the set value within a freely defined range, alarms in case of exceeding upper/lower threshold, and cuts off heating in case of overheating.

Self-diagnostic system: For anomaly detection
Alarm: Visual and audible

Basic equipment

Shelves: See product sheets.
Standard content: Factory calibration certificate at +37 °C included
Door: See product sheets.

Alimentation 220 V
Plage de régulation de la température Ambient temperature +5 to 80 °C
Stabilité ±0,3 °C
Type d'affichage Graphique couleur