Fluke 1664 FC - Installation tester with TRUTEST ADV software
-
Isolation measurement
-
Circuit breakers test
-
Lite license code
1664 FC Installation Tester
The Fluke 1664 FC brings you Fluke reliability, ease of use, and all the testing power needed for daily installation tests.
- Measures up to 500 VAC/DC TRMS.
- Continuity test
- Insulation from 100 V to 1000 V
- Presumed fault current to earth, PSC test. Differential circuit breaker testing (trip time and current)
- Phase sequence indication.
- Motor winding measurement by continuity test (at 10 mA)
- Insulation safety pre-test and resolution to mΩ for loop and line impedance
TRUTEST ADV
The Fluke TruTest software is designed to eliminate problems related to managing data from traditional electrical systems and report generation. Whether you are testing fixed wiring installations or devices in an office, checking repairs in a workshop, or performing annual inspections, proper data management is essential for producing easily understandable customer reports.
Compatible with a growing list of Fluke and Beha-Amprobe test and measurement instruments, TruTest software allows you to import measurement results directly from your test instruments, manage files transferred from instruments, or manually enter data as needed, all quickly and easily.
With a streamlined user interface and intuitive workflow, measurement data can be easily edited into printable test reports and certificates with your company's logo and electronic signature.
- Easily manage measurement data
- Quickly create test certificates and reports
- Free updates for 5 years after installation
- Simplified data collection and database transfer
- Manual data entry
- Intuitive user interface
- Simple and fast to use
Comes with:
- 6 AA batteries (IEC LR6)
- C1600 hard carrying case
- Zeroing adapter
- Heavy-duty power cord
- Standard measurement cord set STD
- Padded waist strap for transport
- Quick reference guide
- TP165X remote control cord and probe
- Instruction manual on CD-ROM
Caractéristiques techniques
Measurement functions:
- Continuity at L-N, N-PE inputs - Testing of pure DC sensitive residual-current devices (Type B) - Earth resistance - Voltage and frequency - Wiring polarity tester, detects cut N wires - Insulation resistance - Continuity and resistance - Measure motor windings with continuity test - Loop and line resistance - Presumed earth fault current (PEFC/IK) - Presumed short-circuit current (PSC/IK) - Differential switching time - Differential tripping level (ramp test) - Measures current and tripping time for type A and AC differentials in a single test - Variable differential current - Automatic differential test sequence - Phase sequence indicator |