Fluke 1662 SCH - Installation tester with TRUTEST ADV software
-
Measure up to 500 VAC/DC TRMS. Continuity test; Insulation from 100 V to 1000 V (and 50 V for 1663/4)
-
Lite License Code
Installation Tester 1662 SCH
The Fluke 1662 brings you Fluke reliability, ease of use, and all the testing power needed for daily installation testing.
- Measures up to 500 VAC/DC TRMS
- Continuity test; Insulation from 100 V to 1000 V (and 50 V for 1663/4)
- Insulation pre-test safety and mΩ resolution for loop and line impedance
- Presumed earth fault current, PSC test
- Differential circuit breaker test (trip time and current)
- Phase sequence indication. Motor winding measurement by continuity test (at 10 mA)
TRUTEST ADV
Fluke TruTest software has been designed to eliminate issues related to managing data from traditional electrical systems and report generation. Whether you are testing fixed wiring installations or devices in an office, checking repairs in a workshop, or conducting annual inspections, proper data management is essential for producing easily understandable client reports.
Compatible with a growing list of Fluke and Beha-Amprobe test and measurement instruments, TruTest software allows you to import measurement results directly from your test instruments, manage transferred files from instruments, or manually enter data as needed, all quickly and easily.
With a streamlined user interface and intuitive workflow, measurement data can be easily edited into printable test certificates and reports with your company logo and electronic signature.
- Easily manage measurement data
- Quickly create test certificates and reports
- Free updates for 5 years after installation
- Simplified data collection and database transfer
- Manual data entry
- Intuitive user interface
- Simple and fast to use
Delivered with: - 6 AA batteries (IEC LR6) - C1600 hard carrying case - Zero adapter - Heavy-duty power cord - Standard measurement leads STD - Padded waist strap for transportation - Quick reference guide - TP165X remote control cord and probe - Instruction manual on CD-ROM
Caractéristiques techniques
- Measurement function
- Voltage and frequency
- Wiring polarity tester, detects cut N cords
- Insulation resistance
- Continuity and resistance
- Measure motor windings with continuity test
- Loop and line resistance
- Presumed earth fault current (PEFC/IK)
- Presumed short-circuit current (PSC/IK)
- Differential switching time
- Differential tripping level (ramp test)
- Measure current and tripping time for type A and AC differentials with a single test
- Differential variable current
- Automatic differential test sequence
- Phase sequence indicator
|