Captair Smart 321 filtration hood with HEPA/BE+ filter - ERLAB

Sku: 792763
Erlab
The strong points
  • Approved hoods according to the NF X 15-211 standard.

  • The exclusive detection system constantly monitors the saturation status of your filters.

  • Good visibility and optimal comfort for work thanks to the inclined front.

€4,370.00 €5,244.00

Life in the laboratory becomes + Simpler + Safer A safer protection - Exclusive Erlab filtration technology - Filtration and containment performance compliant with the AFNOR NFX 15 211 standard - Main filter saturation sensors for Solvents or Acids or Formaldehyde (optional) - Safety filter in case of main filter saturation (optional) - Real-time control of the air speed in the front - Erlab Safety Program: study and validation of the application, certification of use, monitoring of the device's use (to be requested) - Connected device that allows receiving safety notifications and usage reports Easier use Light and sound pulses communicate real-time operating states in case of: - Exceeding the previously defined operating time - Decrease in the front air speed - Main filter saturation - Ventilation malfunction Flexibility - Evolutive filtration column in case of application changes - Simple and fast relocation Savings - No connection cost to the building's ventilation - Annual energy cost < 100 € - Cost of replacement filter covered by energy savings, compared to a connected extraction hood Environment - No release of chemicals into the atmosphere - Collection and disposal of used filters with energy recovery - Very low energy consumption

Captair Smart 321 Hood HEPA Filter BE+ Filter Additional equipment not included with the hood (to be ordered separately if needed): Worktop* Supporting furniture* Transparent back panel* Molécode* * to be found in the "RELATED PRODUCTS AND RESOURCES" section

Dimensions intérieures (L x H x P) 700 x 822 x 470 mm
Dimensions extérieures (L x H x P) 800 x 1110/1285 x 620 mm __null__
Type de filtre BE + HEPA
Largeur 800 mm
Caractéristiques techniques
The hood is delivered in kit form to be assembled by the customer. (a CD or assembly instructions are provided)
The assembly and commissioning are the responsibility of the customer.
These new ErLab hoods, known as SMART technology, require safety parameter validation before initial use.
To do this, it will be necessary to have a computer and an RJ45 connection, with a user manual provided.

The price includes delivery to the unloading dock of the establishment.
Any other service such as:
- handling to the laboratory
- assembly of the device,
- technician visit
will be the subject of a new quote.
A "commissioning" service (visit by an ErLab technician, complete assembly of the device, airspeed control, user training, drafting and delivery of the report) by ErLab is possible by quote and only in metropolitan France.