Benchtop Conductivity Meter OCD218 - ORIGALYS

Sku: 704890
Origalys
The strong points
  • Pack with platinum glass conductivity cell

  • Robust

  • Reliable and fast results

€1,220.00 €1,464.00
- +
On order

OrigaLys was founded by four R&D engineers from Radiometer®. Drawing on their experience, OrigaLys now offers you the OrigaMeter range Conductimeter: OCD218. This conductimeter features an easy-to-use interface and ideal characteristics for teaching purposes. Durable and with a 5-year warranty (excluding consumables), it can be integrated into an existing set of conductimeters because its interface is compatible with those of older Radiometer® conductimeters. The instructions are simple and in French on a large display. Indeed, the latest calibration parameters are stored in the instrument and can be exported to a .txt file via USB transfer. The conductimeter is compatible with almost all ExAO systems (including Regressi) thanks to its outputs (digital and analog). The measured data can be exported and/or viewed in real time on the display. For data transfer, three possibilities: - Real-time data retrieval in Regressi is possible via an RS232 connection. It is then possible to analyze the results on Regressi or very easily copy and paste the data to Open Office. For computers without a native COM port, a USB to RS232 adapter (ref. 471 093) is required. - Analog output. Two measurement modes are available to facilitate the operator's work: manual mode, which allows continuous reading of conductivity displaying the stability indicator, or automatic mode where the result is frozen when the signal is stabilized (100% stability). - USB port.

Compensation de température - 10°C to 110°C
Gamme de température -10°C to 110°C
Mesure de pH Précision Non communiqué
Étalonnage Automatique, manuel et fixe
Gamme de mesure 0,01 µS/cm à 1S/cm
Type Paillasse
Sorties Analogique, RS232, USB
Caractéristiques techniques
Conductivity: 0.01 µS/cm to 1 S/cm
Resistivity: 1 ohm/cm to 100 MOhm/cm
Temperature: -10°C to 110 °C
Resolution:
Conductance: 1/32000
equivalent to 0.3 nS (range 10 µS) / 3 µS (range of 100 mS)
Tolerances:
Conductivity: ± 0.5% of reading ± 3 digits
Resistivity: ±1% typical of reading ± 3 digits
Temperature: ± 0.5 °C
Range Selection:
Automatic: conductivity, resistivity
Manual: conductivity
Result Units:
Conductivity: S/cm or S/m
Resistivity: Ω.cm or Ω.m
Outputs: USB, RS232, and Analog
Inputs/Outputs:
Input for connecting a cell (6-pin mini-din plug) and a temperature probe.
RS232C I/O for printer or microcomputer. Selectable communication speed.