Fluke 377/E - Non-contact Clamp Meter

Sku: 297190
Fluke
The strong points
  • Measure voltage and current with the jaw

  • Faster and safer tests

  • Perform three-phase voltage and current tests in 3 quick steps

€800.00 €960.00
- +
On order

Voltage and Current Measurements with FieldSenseMC Technology

The Fluke 377 FC true-rms clamp meter uses FieldSenseMC technology to make testing faster and safer, all without contact with an energized conductor. You get accurate measurements of voltage and current through the clamp jaw. Simply attach the black test lead to any electrical ground, place the clamp jaw around the conductor, and see reliable and accurate voltage and current values on the screen.

Measure Extremely High Current with iFlex® Probe

Use the included iFlex flexible current probe to measure up to 2500 A of alternating current. The iFlex probe allows access to large conductors in tight spaces.

Perform Three-Phase Measurements in Simple and Quick Steps

- Conduct three-phase voltage and current tests in 3 easy steps
- Complete set of phase-to-ground and phase-to-phase values calculated and displayed on the meter
- Values are also shown on your smartphone and saved in the cloud via Fluke Connect software
- Phase rotation automatically calculated and illustrated on Fluke Connect software
- No more handwritten notes or complicated math.

Comes with: - iFlex flexible current probe (18 inches; 48 cm) - TL224 silicone-insulated test leads - Adjustable length test probes TP175 - AC285 grounding clip (black, quantity 1) - TPAK magnetic hanging kit, with 9-inch suspension strap (23 cm) - Premium carrying case - Quick reference guide

Caractéristiques techniques
General Specifications
- Maximum general voltage (between any terminal and earth) : 1,000 V
- Battery: Type: 2 AA IEC LR6 alkaline batteries, autonomy: 200 hours
- Display: Dual display
- Automatic standby: 20 minutes

AC current: jaw
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2% ± 5 digits (10 Hz to 100 Hz), 2.5% ± 5 digits (100 Hz to 500 Hz)
- Crest factor (50/60 Hz): 3 to 500 A, 2.5 to 600 A, 1.42 to 1000A, add 2% for CF>2

Variants
- Non-contact voltage: Yes
- CAT rating: CAT III 1000 V
- True RMS: Yes
- Capacitance / resistance: 999.9 uF/ 60 kΩ
- Diode / continuity: No / yes
- Low-pass filter: Yes
- Min / max / average hold: Yes
- Frequency: 500 Hz
- AC / DC voltage: 1000 V / 1000 V
- AC / DC current: 2500 A‡/1000 A
- Field detection voltage: 1000 V
- Display: V and A
- Power quality indicator: No
- Three-phase measurement: Yes
- Phase rotation: Yes
- Visual continuity: Yes
- Reporting software: No