Sefram A1532-XA - Tester for charging stations
Tests that can be performed with the A1532-XA alone:
• Detection of terminal voltage presence (indicator)
• Simulation of PP driver resistances to emulate the electric vehicle with various charging currents
• Simulation of the EV status (disconnected, connected on standby, charging with ventilation, charging without ventilation)
• Testing and visualization of the charging station's reaction based on different simulations
Perform a load test:
Verify the operation of the integrated meters on the charging stations, and ensure that the station provides a current by connecting a load, single-phase or three-phase, up to 13A, to the 2P+T socket or to the banana plugs available on the device.
Tests that can be performed with the A1532-XA connected to an installation controller:
• Voltage measurement
• Loop impedance measurement
• Contact voltage measurement
• RCD test
• Insulation measurement on the charging station (de-energized)
• Addition of visual tests in a report (only on MW9665 and MI3155ST)
• Export of all tests for the creation of a professional report (only on MW9665 or MI3155ST)
Comes with: carrying case
Caractéristiques techniques
Input voltage: 400V (3 phases)
Frequency: 50Hz Maximum test current: 267A (10ms) for intermittent operation Safety (IEC61010): 300V CAT II Dimensions: 250 x 100 x 70 mm Weight: 0.90 kg Warranty: 1 year |