Metrix OX9062 - Portable Oscilloscope 2x60 MHz
Oscilloscope: triggering, automatic measurements, MATH functions
An oscilloscope with complex triggering functions to only record what is necessary and catch all faults.
The OX 9000 offers advanced triggering options, in addition to the main triggering possibilities on the front: on pulse width, counting, delay.
- The delay mode allows the observation of any event with the maximum resolution, even if it occurs long after the actual triggering, even on 2 different channels.
- The counting mode makes it possible to count events prior to triggering, in order to verify the content of digital frames, for example.
The triggering can be associated with a second "auxiliary" signal different from the "main" signal.
Automatic measurements: up to 20 parameters of a signal for each channel.
Fast Fourier Transform (FFT) in real-time:
- measurement of different harmonics or signal distortion
- analysis of an impulse response
- search for noise sources in logic circuits
Harmonics analysis:
Harmonics analysis on the 4 channels is performed up to the 63rd rank to meet the requirements of standard EN 50160 (THD on a minimum of 50 ranks), with a fundamental frequency between 40 and 450 Hz.
It is possible to pre-select the fundamental frequency for standards (50 Hz, 60 Hz, and 400 Hz).
This function improves analysis performance, and especially measurement when the level of a harmonic rank is higher than the fundamental.
It is possible to simultaneously visualize harmonic analysis of two or four channels: RMS level, harmonic distortion, harmonic frequency, phase of the harmonic relative to the fundamental.
Multimeter:
A simple selection of the dedicated icon provides access to the multimeter without changing the measurement input channels. A true 8,000-point TRMS digital multimeter with two or four channels, the OX 9000 performs the following measurements:
XX amplitude (DC or AC voltage and current, power, temperature, etc.)
XX resistances, continuity, capacitance
XX component testing
Temperature measurement is done via Pt 100 and Pt 1000 sensors, or type K thermocouples through dedicated PROBIX sensors.
Recorder/logger
This is the trend recording mode of the multimeter mode. For monitoring over time the variations of physical or mechanical phenomena, a true fast digital recorder in the instrument.
It allows acquisition speeds of up to 40 μs between 2 measurements and recordings can range from 2 seconds to one month.
Harmonics
4 simultaneous channels
Lissajou: XY
Measurement between H and V cursors: T1, T2, Dt, 1/Dt, V1, V2, dV, Ph
State
An oscilloscope SCOPIX IV delivered with: 1 carrying case 1 power supply/charger block PA40W-2 and 1 EURO 2P power cord 1 Li-Ion battery pack 1 stylus 1 Ethernet cable 1 USB cable 2 safety leads (red, black) 2 Ø 4 mm test probes (red, black) 2 or 4 voltage probes depending on models 1 μSD card (8 GB) 1 USB/μSD adapter 1 hand strap 1 PROBIX BANANA 1 USB installation procedure for using ScopeNet data export software on CD-ROM 1 operating manual .pdf on CD (>5 languages) 1 paper quick start guide 1 safety sheet in 20 languages
Nombre de voies | 2 |
Taille de l'écran | 7" |
Bande passante | 60 MHz |
Profondeur mémoire | 100 Kpts |
Échantillonnage monocoup | 2,5 Géch/s |